Features:
1. Fully automated, Discrete, Random access
2. Total open setting of items, supported different reagents from different countries.
3. Reversed optics and imported photosensor make sure the precision of detection results.
4. Microsring injector imported from Germany assures the veracity of a trace of samples, sample step by 0.1 UL, reagent step by1 UL
5.24 hour non-stop working, convenient emergency function with inserting emergency at random.
6. Implementing analysis of ultra-trace reaction solution to 180 UL, and saving more reagents.
7. Discrete cuvette, preventing from cross-infection, and be washed and reused, making sure accurate result and save cost.
8. Perfect self-detection function makes sure the analyzer in order and accurate result.
9. Software is easy to learn and use. And test report can be printed.
10. Perfect function of quality control management is convenient for users to manage the clinical test result.
11. Detecting in the whole reaction process with reaction curve, convenient for users to monitor thoroughly and scientifically analyze the detection data.
12. Supporting software can implement the function of detecting surplus reagent through liquid level induction of reagent probe.
Reference Pictures and Illustrations
I. 60 sample positions for primary tubes or serum cups, sufficient to meet the demand for use
II. Adopting state-of-the-art pattern of cleaning, washing cuvettes automatically, as well as recording and deducting the base value of each cuvette, meanwhile eliminating differentials between cuvettes.
III. 45 reagent positions, non-break refrigerating system with independent switch.
IV. High sensitive liquid level induction system, automatic liquid level detection, collision protection, automatically cleaning inside and outside of probes and wave-poured washing canal, make sure wash probe clean. Hydrophobic membrane treatment for both inside and outside and no cross-infection.
V. High precision Microsring injector is imported from Germany. Special glass is adopted in the inner wall, and makes sure sample precision and resistant to abrasion, meanwhile solid organic glass is adopted in the outer wall. Precision for sample injector can reach 0.1 UL, and for reagent injector can reach 1 UL. Sample injector can absorb sample volume from 2 to 50 UL each time and the minimum limit for sample can reach 2 UL.
Model |
HP-DIAMOND |
Dimensions (W x D x H) |
1020*830*1220 |
Analysis method |
End point, two points, kinetic method, turbidimetry |
Wavelength range |
340, 405, 510, 546, 578, 600, 660, 700
(three of them can be defined by the users), adopting reversed optics |
Reagent volume |
R1: 25-300ul; R2: 10-150ul(step by 1ul), support reagent from different countries |
Receiver |
8 imported photo receivers |
Sample volume |
3 ul-50ul (step by 0.1ul),
high precision injector (dilution vessel) is prepared |
Cuvette |
120 independent reaction cuvettes(optical path length 6mm) |
Calibration |
one-point, multipoint |
Test/H |
400 |
Shipping Dimensions,
(W x D x H) |
1150*980*1350 |
Software |
Windows 2000 professional or windows XP.
Have plenty of functions of inquiries, convenient to use |
Printout |
user can modify the printing format by his own |
Electrical |
AC220V + 22V 50Hz + 1Hz |
Certification |
CE, ISO9001, ISO14001, ISO13485, FDA |