Three Arm Ceiling Shadowless Lighthing System
One arm with LED lamp and build-in photo system
One arm with Halogen Lamp
One arm with LED display
- LED Ceiling Lamp
1,Through EMC electromagnetic compatibility testing, ensure that weak lines in the internal information system are not affected by electromagnetic signal interference (provide a national level testing agency testing report).
2,Adopting a new type of LED cold light source, the illumination can reach 40000-180000Lux, which can achieve stepless dimming and non multi range adjustment; The color temperature is in the range of 3700K-5000K, and there is no polar dimming or multi range adjustment. While meeting high illuminance, adjust lighting parameters according to the needs of different surgeons to make their perception of light soft and not dazzling. (Provide testing reports from national testing institutions)
3,The color rendering index is 85-98, which truly reflects the color of human tissue and is suitable for various surgical scenarios, greatly reducing the visual fatigue caused by long-term surgery for medical staff. (Provide testing reports from national testing institutions)
4, Adopting imported LED light emitting chips from Germany, the chip has a service life of over 80000 hours. (Import declaration list and supporting materials need to be provided)
5,The luminescent chip adopts sub item control technology to ensure that a single LED is damaged and does not affect the normal operation of the surgery.
6,The depth of the light column is ≥ 1300mm, meeting the lighting needs of different surgeries. (Provide testing reports from national testing institutions)
7,The temperature rise of the surgeon's head should be less than 1 ºC to avoid tissue drying caused by rapid blood coagulation at the wound due to temperature rise, which may affect the operation.
8,The lamp holder controller is displayed on a LCD screen.
9,The controller can not only adjust the power switch, illumination, and color temperature, but also has a one button mode switching function, with no less than 2 switching modes, which can be switched with one button for different surgical scenarios.
10,The lampshade shell is made of high-quality aluminum material, and the surface adopts high-voltage electrostatic spraying technology. Imported environmentally friendly antibacterial plastic powder is used to ensure that the product meets surgical hygiene requirements, with a matte surface and no glare. (Provide supporting materials)
11,The round lamp cap of the lamp body is ≥ 700mm, with ultra-thin streamline design, and the thickest part is not more than 10cm, which can achieve excellent laminar flow effect.
12,By rotating the disinfection handle, the size and focusing effect of the shadowless light spot can be adjusted, with a spot diameter of 160-280mm, suitable for various surgical lighting needs.
13,The central disinfection handle can be disassembled at will, with a temperature resistance of no less than 134 ºC and a high pressure resistance of no less than 205.8kPa, making it convenient for high-temperature and high-pressure steam sterilization.
14,The lamp arm adopts a linkage structure of no less than five sets of universal joints, which is easy to operate, precise in positioning, and can rotate 360 ° freely; Equipped with fatigue correction device and positioning touch adjustment device, positioning and adjustment can still be easily carried out after long-term use. (Provide supporting materials)
15,The lamp holder is equipped with a handle that covers not less than a quarter of the outer ring of the lamp holder, making it easy for medical staff to operate and angle adjustment more convenient.
16,The internal structure of the lamp head adopts an excellent arc design, with no less than 8 built-in partition modules and no less than 80 luminous chips. It is illuminated by multiple point light sources, and the light spot adjustment is flexible, making the light spot illumination more uniform. When the surgical lamp is partially blocked, it can also achieve a perfect shadowless effect.
17,The rotating arm adopts high-quality octagonal seamless steel pipes, which are formed in one go, with a beautiful appearance and more flexible and convenient rotation.
18,The optical circuit adopts CPU control, and the brightness and color temperature of the light area are uniformly increased or decreased during adjustment, with brightness memory function.
19,Power supply voltage AC100-240V 50/60HZ
Overall Reflection Halogen Lamp
1,Through EMC electromagnetic compatibility testing, ensure that weak lines in the internal information system are not affected by electromagnetic signal interference (provide a national level testing agency testing report).
2,The illumination can reach 40000-180000Lux and achieve ten levels of continuous dimming; Provide a color temperature close to natural sunlight of 4500 ± 250K, ensuring that the surgeon can clearly and accurately identify the colors of blood vessels, tissues, nerve bundles, etc. in the surgical area. (Provide testing reports from national testing institutions)
3,Color rendering index ≥ 97%, truly reflecting the color of human tissue, suitable for various surgical scenarios, greatly reducing the visual fatigue caused by long-term surgery for medical staff. (Provide testing reports from national testing institutions)
4,The lamp holder adopts imported lamp holders and imported famous halogen tungsten bulbs, with an average service life of ≥ 1500 hours
5,The depth of the light column is ≥ 1200mm, meeting the lighting needs of different surgeries. (Provide testing reports from national testing institutions)
6,The head temperature rise of the surgeon is less than 2 ºC, to avoid tissue drying caused by rapid blood coagulation at the wound due to temperature rise, which may affect the operation.
7,The surgical lamp is equipped with a manual controller and lamp holder control panel, with 20 levels of dimming.
8,Single lamp head with dual bulb design, when the main bulb fails, the secondary bulb can automatically switch to light up within 0.2 seconds, ensuring the continuation of surgery, and there is a warning of damage to the main and secondary bulbs; The replacement of the main and auxiliary light bulbs is simple and convenient.
★ 9,The lampshade shell is made of high-quality aluminum material, and the surface adopts high-voltage electrostatic spraying technology. Imported environmentally friendly antibacterial plastic powder is used to ensure that the product meets surgical hygiene requirements, with a matte surface and no glare. (Provide supporting materials)
10,The lamp body is circular, and the diameter of the lamp head is ≥ 700mm
11,By rotating the disinfection handle, the size and focusing effect of the shadowless light spot can be adjusted, with a spot diameter of 160-280mm, suitable for various surgical lighting needs.
12,The transparent glass of the lamp head is made of shockproof, high-strength, and corrosion-resistant materials, which are sturdy and durable, easy to clean, and will not be affected by radiation, wiping, and long-term use.
13,The central disinfection handle can be disassembled at will, with a temperature resistance of no less than 134 ºC and a high pressure resistance of no less than 205.8kPa, making it convenient for high-temperature and high-pressure steam sterilization.
14,The lamp arm adopts a linkage structure of no less than five sets of universal joints, which is easy to operate, precise in positioning, and can rotate 360 ° freely; Equipped with fatigue correction device and positioning touch adjustment device, positioning and adjustment can still be easily carried out after long-term use. (Provide supporting materials)
15,The lamp holder is equipped with a handle that covers not less than a quarter of the outer ring of the lamp holder, making it easy for medical staff to operate and angle adjustment more convenient.
16, The reflector surface is made of imported aluminum oxide material, and the number of reflective lenses is ≥ 5280, in order to meet the surgical shadowless needs to the greatest extent possible.
17, The rotating arm adopts high-quality octagonal seamless steel pipes, which are formed in one go and have a beautiful appearance, making rotation more flexible and convenient.
★ 18, The optical circuit adopts CPU control, and the brightness and color temperature of the light area are uniformly increased or decreased during adjustment, with brightness memory function.
19, Power supply voltage AC100-240V 50/60HZ
Photo System
It can meet the high-definition and high-definition shooting needs in clinical skill training, standardized training, surgical video recording, surgical demonstration, academic conferences, surgical live streaming, remote guidance, digital operating rooms, school medical skill teaching, and other scenarios. It supports use in different environments such as shadowless strong light and daily indoor lighting.
|
10 times up to 4.35 million 1/2.8 "CMOS High definition surgical field machine |
Camera |
Sensor |
1/2.8" CMOS |
Scanning |
progressive scanning |
Signal |
PAL/NSTC |
Video |
SDI output |
Resolving |
50HZ:50fps(1920X1080) 60HZ:60fps(1920X1080) 50HZ:25fps(1920X1080) 60HZ:30fps(1920X1080) |
Min Illumination |
Color:0.05Lux @ (F1.6,AGC ON) |
Signal to noise ratio |
>52dB |
Camera Lens |
Focal length |
4.7-47mm,10x optical zoom |
Aperture value |
F1.6-F3.0 |
Horizontal field of view angle |
58.6-6.4degree(Wide angle telescopic) |
Close-up range |
120mm-800mm(Wide angle telescopic) |
Parameter Settlement |
Focus mode |
Semi-auto/Auto/Manual |
Exposure mode |
Auto Exposure/Aperture Priority/Shutter Priority/Manual Exposure |
Electronic shutter |
1/1s to 1/30,000s |
white balance |
Automatic 1/Automatic 2/Indoor/Outdoor/Manual/Sodium lamp/Fluorescent lamp |
gain |
16 grade,adjustable |
Wide Dynamic |
Off/On, 15 level adjustable |
Digital Noise Reduction |
3D |
Len Initialization |
Build-in |
Image quality adjustment |
Brightness, contrast, sharpness, saturation adjustable |
Number doubling |
10 |
Interface functions |
external interface |
SDI/RS485/Power/UART |
External communication |
Pelco P/Pelco D/VISCA |
Regular Information |
Power Source |
DC12V±25% |
Working temperature and humidity |
-10ºC to 60ºC,No more than 90%RH |
Power |
5W |
External Size |
43.5*45.4*68.8mm |
Net Weight |
190g |