HP-AA560B5 High End Clinical Anesthesia Machine
HP-AA560B4 Anesthesia apparatus with its ergonomic design,integrates a concise and smooth structure and high mobility.The microcomputer-controlled Ventilator adopts exported sensors and other components.Its scientific and proper design as well as rigorous production process are what demonstrate the inner quality of us:mechanical ventilation is made secure and visible by the folded respiratory bellows,and the security of air supply is guaranteed by pneumatic transmission and measurement system.With multiple modern technologies applied,the Anesthesia Machine is both outstanding in performance and versatile in functions.
Main Advantages:
The Ventilator adopts microcomputer control with high-definition 5.7" LCD display, integrating the functions of respiratory control and displaying the monitoring parameters. It is versatile in function and excellent in performance.
The high-precision Vaporizer is designed with a stable concentration output, automatic compensation for pressure, temperature and flow rate. And it is available to choose two kinds of gas from Halothane, Enflurane, Isoflurane, and Sevoflurane, ensuring a successful anesthesia operation.
High-definition four-tube flowmeter, designed with stoppers for oxygen and nitrous oxide to control the output oxygen concentration.
Reliable pneumatic transmission system.
Economic and proper configuration of technologies, optional as required by the Customer.
Modularized design and upgrading. Upgrading is available as required by the Customer.
Composition of Anesthesia
Main body: High-strength engineering plastic rack, light, beautiful and corrosion resistant
Scope of application: Adult,child
Gas source: O2: 0.27~0.55MPa N2O: 0.27~0.55MPa
Flow meter: O2: 0.1~1.0L/min 1.1~10L/min
N20: 0.1~1.0L/min 1.1~10L/min
O2, N2O linkage and N2O Stopper:
When using nitrous oxide, oxygen concentration>25%;
When the oxygen pressure<0.2Kpa, the flow of nitrous oxide would be cut off.
Flow rate of rapid oxygen supply: 25~75L/min
Low oxygen pressure alarm: There will be sound alarm when the oxygen pressure < 0.2MPa
Vaporizer: It has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0~5 vol%.
Among Halothane,Enflurane,Isoflurane and Sevoflurane,two can be chosen for application as required by the customer. And vaporizers that are imported with original packaging are also available.
Respiratory circuit: Working mode: all-close, semi-close, semi-open
APL: 0.5~7 k
Respiratory Bellows: Bellows for adults : Tidal volume range:0~1,500 ml
bellows for children : Tidal volume range:0~300 ml
Composition of Ventilator
Display mode: High-definition 5.7" LCD screen display
Ventilation mode: IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH
Ventilation parameters: Tidal volume 50~1500 ml
Rate: 2~99 bpm
SIMV rate: 2~20 bpm
I:E 2:1~1:8
Inspiratory trigger pressure -1.0~2.0 kPa
PEEP: 0~2.0 kPa
Pressure range: 1.0~6.0 kPa
SIGH: 1.5 times the inspiratory time
Parameters for ventilation monitoring: Tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure
Monitoring of oxygen concentration: (21%~100%)
Security Alarm System
Oxygen Concentration alarm: Upper limit setting range (50%~100%)
Low limit setting range (15%~50%)
Airway pressure alarm: Upper limit setting range 1.0~6.0 kPa
Low limit setting range 0.4~2.0 kPa
Per-minute ventilation volume alarm: Upper limit setting range 3.0~30L/min
Low limit setting range 1.0~10L/min
Sustained high-pressure alarm It will give alarm when stress have consistently been higher than 2.5 kPa
Suffocation alarm: It will give sound and light alarm if there is no tidal volume input for 15 seconds
Power alarm
Power: AC 220V±10% 50Hz±1Hz
(UPS, Storage battery)
(Mechanical Arms)
(End-expiratory CO2 monitoring)
Package Details: Plywood Case:770*780*1440mm,N.W./G.W.:56/92kgs
800*430*380mm,N.W./G.W.:26/37kgs
Brief View:
Model |
HP-AA560B1 |
Display mode |
4.8" LCD screen |
Ventilation mode |
IPPV, MANUAL |
Power |
AC 220V±10% 50Hz±1Hz |
Net Weight |
50kgs |
Package Size |
690*680*1300mm |
Note:More details for this model or models can refer to HEPO INTERNATIONAL official website or contact us directly.