Customization: | Available |
---|---|
Classification: | Biochemical Apparatus |
Type: | Biochemistry Analyzer |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1.Precise sample and reagent aspiration |
2.Built in bubble elimination prior to washing |
3.High pressure interior probe wash |
4.Carry-over<0.05% |
1.Light-spot Flatting Technology facilitates lower reaction volume |
2.24 hour non-stop refrigeration at 4-10ºC |
3.Minimum sample volume:2ul |
4.Reagent volume:20-25ul |
5.Minimum cuvette volume:150ul |
1.Front loaded reagent compartment for easier access |
2.Easy access for routine maintenance and troubleshooting |
3.Easy to connect pipeline and cable |
1.Real-time analytical and carousel status monitoring |
1.Levy-Jennings chart and Twin-plot chart |
2.QC Out-of-Range real-time alarm |
1.Historic date recall from reagent/calibrator/control archive |
2.Intuitive software,easy historical results |
1.User-defined customizable reflexive assays |
2.Multiple reflexive criteria may apply to a single assay |
3.A single reflexive criteria may apply up to 20 assays |
System Function | |
Fully automated,discrete,random access,STAT,urine and homogeneous immunoassays,STAT sample priority | |
Throughput | Constant 300 tests/hour,Massuring principles:Absorbance Photometry,Turbidometry |
Methodology | End-point,Fixed-time,Kinetic,Single/uual/Triple/Quadruple reagent chemistries,Monochromatic/Bichromatic |
Programming | User defined profiles and calculation chemistries |
Sample Handling | |
Sample tray | 120 positions for sample primary or secondary tubes and sample cups |
Sample volume | 2~100ul,step by 0.1ul |
Sample probe | Liquid level detection,clot detection and collision protection |
Probe cleaning | Interior and exterior automatic probe washing carry-over<0.05% |
Reagent Handling | |
Reagent tray | 80 positions in refrigerated compartment (4~10ºC) |
Reagent volume | R1:150~300ul,R2:20~150ul |
Reagent probe | Liquid level detection, collision protection and inventory check |
Probe cleaning | Interior and exterior automatic probe washing |
Reaction System | |
Reagent rotor | Rotating tray,81 cuvettes with automatic washing |
Cuvette | Optical length 5mm |
Reaction volume | 150~450ul |
Operating temperature | 37ºC |
Temperature fluctuation | ±0.1ºC |
Mixing system | 2 independent mixers |
Optical System | |
Light Source | Halogen-tungsten lamp |
Photometer | Reversed optics photometry |
Wavelength | 340nm 405nm 450nm 510nm 546nm 578nm 630nm 670nm |
Absorbance range | 0~4.0Abs(10mm conversion) |
Resolution | 0.0001Abs |
Control and Calibration | |
Calibration mode | Linear(one-point,two-point and multi-point),Logit-Log 5p,Spline,Factor |
Operation Unit | |
Operation system | Windows XP SP2 or SP3/ Windows 7 Home Basic |
Interface | RS-232 |
Working Conditions | |
Power Supply | 200~240V 50/60HZ 1000W or 100~120V 60HZ 1000W |
Temperature | 15~30ºC |
Humidity | 35~85% |
Water consumption | 18L/hour,De-ionized water |
Dimension | 912mm*721mm*570mm(W*D*H) |