Popular Class II Biological Safety Cabinet in Papua New Guinea

Product Details
Customization: Available
Material: Stainless Steel
Type: Medicine Cabinet
Manufacturer/Factory, Trading Company, Group Corporation
Gold Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 14001, GMP, ISO 13485
  • Popular Class II Biological Safety Cabinet in Papua New Guinea
Find Similar Products

Basic Info.

Model NO.
BSC-1300IIA2-X
Layer
1 Layer
Usage
Hospital, School, Company, Research Institute
Color
Blue
Customized
Customized
Condition
New
External Dimensions (W X D X H)
1300*850*2200
Internal Size(mm)/ W*D*H
1100*600*660mm
Height
635mm
Inflow Velocity/ Down Flow
0.53 M/S;0.33 M/S
Transport Package
Standard Packing
Specification
ce iso sgs
Trademark
hepomed
Origin
Zhengzhou of Henna
Production Capacity
10000units

Product Description

Class II Biological Safety Cabinet
The Class II biological safety cabinet is an open-front, ventilated cabinet with negative pressure inside. The Class II biological safety cabinet will provide personnel, environment and product protection.It's always used for doing dangerous experiments or infective experiments.
 Main Advantages 
1,Remote Control
All functions can be realized through it, the first choice for preventing cross contamination.Much Easy and Safe to control and operation the cabinet.
2,Foot Switch
You can use foot switch to adjust the height of the front window during the test,which is much convenient.It's our unique design.
3,Four Sides Air Course Design
The four side air course designing makes the work area all around surrounded by negative pressure.
4,Timer Reserve Function
Mush useful and safety function,such as the starting timer,the UV sterilization timer,etc.
5,Various Display Screen
Using VFD,LED,LCD digital displaying for various models according to different customers' needed.
6,Filter & UV Life Attention
It can be showed in our VFD display.
7,Safety Power Lock and Cabinet Lock
To make sure nobody else can use the cabinet without allow.
8,Motor Controlled Laminated Glass
Much safety once broken and better effect to prevent the UV light.
9,Audio and Visual Alarm Function (Filter replacement,window over height,air flow abnormal etc.)
10,Interlock Function:UV Lamp and front window,UV lamp and blower,fluorescent lamp,Blower and front window.
 
According to the performance criteria
1  US Standard  ANSI/NSF49:2002
2  European Standard  EN12469:2000
3  Chinese Standard  YY0569-2005
Parameters for Class II A2 Biological Safety Cabinet
 
Main Parameters of Class II A2-X
Model  BSC-1100IIA2-X BSC-1300IIA2-X BSC-1500IIA2-X BSC-1800IIA2-X BSC-2000IIA2-X
Internal size(mm) 900*600*660 1100*600*660 1300*600*660 1600*600*660 1800*600*660
External size(mm) 1100*850*2200 1300*850*2200 1500*850*2230 1800*850*2300 1950*850*2200
Tested Opening Safety Height:≤200 mm
Max Opening 400mm
Inflow Velocity/
Down Flow
0.53 m/s;0.33 m/s
Filter Two HEPA filter,99.999% efficient(0.3 microns)
Front Window Two-layer toughened glass? >5mm
Noise ≤60 dB
UV lamp 18W×1 18W×1 30W×1 40W×1 40wX11
Fluorescent Lamp 21W×2 21W×2 28W×2 28W×2 40WX2
Lighting (Lux) ≥1000 ≥1000 ≥1000 ≥1000 ≥1000
Power(W) 760 1060 1300 1350 1700
Water and Gas Tap Water Tap:1;Gas Tap:1.(Optional)
Waterproof Socket Two,total consumption:500w
Display LCD display
Control System Microprocessor
Airflow System: 70% air recirculation,30% air exhaust
Material Work zone interior is made of 304 stainless steel, 
Body: Epoxy coated cold rolled steel
Standard Base 635mm height
Caster Wheel Universal wheel with brake and leveling feet
Electrical 
Parameter
110~240V/50~60Hz (optional)
Net weight(kg) 240 270 310 350 380
Gross weight(kg) 255 305 350 390 420
Package (mm) 1250*1050*1870 1450*1050*1870 1640*1045*1860 1940*1050*1960 2090*1050*1860
Standard Sets Remote control, Foot switch, UV lamp*2,Fluorescent Lamp,Base Stand,Drain valve
,Waterproof Sockets
Optional 
Accessory
Armrest, Air curtain tester, Formalin fumigation sterilizer,
Ammonium hydrogen carbonate,
neutralizer,Infrared Sterilizer
 
 
 
Main Parameters of Class II B2-X
Model BSC-1100II B2-X BSC-1300II B2-X BSC-1500II B2-X BSC-1800IIB2-X
Internal size(mm)/
W*D*H
940×600×660 1100×600×660 1350×600×620 1600*670*630
External size(mm)
W*D*H
1100×750×2250 1300×850×2200 1500×760×2250 1800*840*2275
Tested Opening Safety≤200 mm
Max Opening 400mm
Air Flow Velocity Inflow:0.53m/s ± 0.025m/s;Down Flow Velocity:0.33 m/s ± 0.025m/s
Filter Pre-filter:Washable,Two HEPA main filter:99.999% efficient(0.3 microns)
Front Window Motorized,two layer laminated toughened glass
Noise ≤62dB
UV lamp 20W×1 20W×1 30W×1 40W×1
Fluorescent Lamp 21W×1 21W×1 28W×1 35W×2
Lighting >=1000Lux >=1000Lux >=1000Lux >=1000Lux
Power 1050W 1350W 1550W 1900W
Tap Water Tap:1 ;Gas Tap: 1 (Optional)
Socket Two,Waterproof,total consumption:500w
Display LCD display
Control System Microprocessor
Airflow System: 0 air recirculation,100% air exhaust
Exhaust Duct 4meters PVC duct,diameter: 300mm
Material Work zone interior is made of 304 stainless steel
Body:cold rolled steel with anti-bacteria powder
Base Height 635 mm
Caster Wheel Universal wheel with brake and leveling feet
Electrical 110~240V/50~60Hz (optional)
N.W. 275kgs 320kgs 350kgs 390kgs
G.W. 350kgs 360kgs 440kgs 470kgs
Main Body Package/mm 1250*1050*1870 1450*1050*1870 1640*1045*1860 1940*1050*1860
Exhaust Blower Package/mm 1060*970*580
Standard Parts Main Body,Bottom stand,Remote control, Foot switch,2 UV lamps and Fluorescent Lamp,exhaust duct, exhaust blower,sockets
Option Items Armrest, Air curtain tester, Formalin fumigation sterilizer,Ammonium hydrogen carbonate
 neutralizer,infrared sterilizer

 