Customization: | Available |
---|---|
Classification: | Physiological Functions of Diagnosis and Monitoring Equipment |
Type: | Patient Monitor |
Still deciding? Get samples of US$ 1990/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Physical Specifications | |||||
Dimension and Weight | Dimension | 32cm (W)*26cm (D)*8cm (H) | |||
Weight | standard configuration: 2.8 kg | ||||
Operation Environment | Power requirements | AC100-240V , 50/60Hz | |||
Power | 50VA | ||||
Temperature | 0-40ºC | ||||
Humidity | 0-93% non-condensing | ||||
Fetal/Maternal Performance Specifications | |||||
Performance Specifications | Display | 10.4 inches (1024×768 pixel) color TFT -LCD | |||
Indicator | Visual on-display and integrated, alarm light, audible alarm | ||||
Battery | Internal rechargeable Li-ion battery power | ||||
Alarm | Visual on-display and integrated, alarm light, audible alarm | ||||
Memory | 24-hours memory for fetal traces 150 groups patient data |
||||
Printer | America standard/international standard Built-in thermal printer (paper width:110mm) 1/2/3cm/min real-time printing speed, fast print speed (stored traces) |
||||
Paper | Z-fold, thermosensitive | ||||
Record Message | ID, name, age, date, time, print speed etc | ||||
CMS | Support connecting to central monitoring station through LAN (TCP/IP) or wireless connection | ||||
Fetal/Maternal Technical Specifications | |||||
Ultrasound (FHR) | Measurement range | US | 30 to 240 bpm | ||
Resolution | Display | 1bpm | |||
Printer | 1bpm | ||||
jitter@200 bpm | ≤3bpm | ||||
Display update rate | 0.25second | ||||
Beat to bea change(max.) for ultrasound | 28bpm | ||||
US frequency | 1MHz±5%Hz | ||||
TOCO | Measurement method | Strain gauge sensor element | |||
Sensitivity | 1 unit =2.5g | ||||
Resolution | 1 unit | ||||
Measurement range | 500 units | ||||
Baseline setting | 0, 5,10, 15, 20 can be selective | ||||
Update rate | 0.25 second | ||||
Auto offset correction | 3 second after connecting the transducer | ||||
Auto zero adjust | TOCO value is set to zero negative following a negative Measure value for 5 seconds |
||||
Auto Fetal Movement (AFM) | Technique | Pulsed doppler ultrasound | |||
Range | 0-100% | ||||
Resolution | 1% | ||||
Automatic fetal movement actograph | |||||
Manual fetal movement marker | |||||
Maternal NIBP(MNIBP) | Operation mode | Manual/automatic/ STAT | |||
Measurement unit | mmHg / kPa selectable | ||||
Test interval | 0-480 minutes | ||||
Accuracy | Max.Std.deviation:8 mmHg(1.1kPa) | ||||
Max. mean Error: ±5mmHg(±0.7kPa) | |||||
Measurement range | Systolic | 30 to 270 mmHg(4 to 36 kPa) | |||
Diastolic | 10 to 245 mmHg(1.5 to 32kPa) | ||||
Mean | 20 to 255 mmHg(2.5 to 34kPa) | ||||
Pulse rate range | 20-250bpm | ||||
Over-pressure protection | Yes | ||||
Maternal SpO2 (MSpO2) | Measurement range | 0%-100% | |||
Resolution | 1% | ||||
Accuracy | ±2% | ||||
Pulse rate range accuracy | ±3bpm |