This hemodialysis machine is specially designed, produced and sold for renal failure patients to receive haemodialysis.It is applicable for chronic renal failure and other blood Purification treatment.
ChoosingReasons:
1,Classical and perfect model designed.
2,Two persons can be trained freely for first time.
3,All accessories or spareparts with tools can be along with hemodialysis machine can be set along
4,Rich knowledge engineer and sales can be serve for you.
5,One year guarantee time,5 years spareparts supplied at least.
Forms of Therapy for Hemodialysis Machine:
Haemodialysis, Isolated Ultrafiltration, Sequential Ultrafiltration, Hemoperfusion, etc.
Main Features:
Intelligent Double Operation System LCD touch screen with button interface Emergency power 30Mins (Optional) Blood Pump
Spare Pump (for standby and also can be used for hemoperfustion). Heparin Pump
Hydraulic compartment(Balance chamber + UF pump). Operation, Alarm information Memory function.
A/B Ceramic proportion pump , High precision, Corrosion-proof, Accuracy
Dialysate
Dialysate temperature: preset range 34.0ºC~39.0ºC
Dialysate flux: 300~800 ml/min
Dialysate concentration: 12.1 mS/cm ~16.0 ms/cm, ±0.1 ms/cm
Dialysate mixing ratio: can set variety ratio.
UF rate Flow range: 0 ml/h ~4000 ml/h
Resolution ratio: 1ml
Precision: ±30 ml/h
Extracorporeal Part
Venous pressure: -180 mmHg ~+600 mmHg, ±10 mmHg
Arterial pressure : -380 mmHg ~+400 mmHg, ±10 mmHg
TMP pressure : -180 mmHg ~+600 mmHg, ±20 mmHg
Blood pump flow range: 20 ml/min ~400 ml/min(diameter:Ф6 mm)
Spare pump flow range: 30 ml/min ~600 ml/min(diameter:Ф8 mm)
Resolution ratio: 1 ml
Precision: error range ±10ml or 10% of reading
Heparin Pump
Syringe size: 20, 30, 50 ml
Flow range: 0 ml/h ~10 ml/h
Resolution ratio: 0.1ml
Precision: ±5%
Sanitize
1.Hot decalcification : Time: about 20 minutes
Temperature: 30~60ºC, 500ml/min.
2.Chemical disinfection :
Time: about 45 minutes
Temperature: 30~40ºC, 500ml/min.
3. Heat disinfection :
Time: about 60 minutes
Temperature: >85ºC, 300ml/min.
Storage Environment Storage temperature should be between 5ºC~40ºC, at relative humidity of no more than 80%.
Monitoring System
Dialysate temperature: preset range 34.0ºC~39.0ºC, ±0.5ºC
Blood leak detection: Photochromic
Alarm when erythrocyte specific volume is 0.32±0.02 or blood leak volume is equal or more than 1ml per liter of dialysate
ZHENGZHOU HEPO INTERNATIONAL TRADING CO.,LTD haizhibo001.en.made-in-china.com
Bubble detection: ultrasonic
Alarm when a single air bubble volume is more than 200µl at 200ml/min blood flow
Conductivity: acoustic-optic, ±0.5%
Main Parameters for Haemodialysis Machine
Model |
HP-HEMAD2000 |
Input Power |
1500w |
Working Environment |
10ºC ~30ºC(at relative humidity of no more than |
|
70%. |
|
) |
Water input pressure |
0.15 MPa ~0.6 MPa |
Water input temperature |
10ºC~30ºC |
Machine Size |
380*400*1380mm(L*W*H) |
Package Size |
680*550*1650mm |
Net Weight/Gross Weight |
88kgs/93kgs |
All disposable accessories or other accessories such as Reprocessor,Dialyzer Rinse Machine,RO Water Machine,Dialysate Dosing Device,Dialysis Chair,Dialyzer,Hemoditoxifier,Anti-cross Infection Joint,Test Paper,Dialysis Catheter,Disposable A.V. Fistula Needel,Disinfectant,Dialysis Concentrate and Powder,Haemodialysis tubing package,etc.
Note:One year quality guarantee and 24 hours phone service for all the products supplied.