Russian Hot Selling Medical Lab Automated Blood Gas Electrolyte Analyzer

Product Details
Customization: Available
Classification: Imaging Diagnostic Equipment
Type: Biochemistry Analyzer
Manufacturer/Factory, Trading Company, Group Corporation
Gold Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 14001, GMP, ISO 13485
Find Similar Products

Basic Info.

Model NO.
HP-ELECTRO1000
Certification
CE, ISO13485
Group
Middle-aged and Old
Technology
ISE
Measurement of Tco2 by Pressure Metho
Yes
Sample
Serum / Plasma / Whole Blood /Urine
Sample Volume
90 UL
Reagent Volume
0.3 Ml
Printer
High Speed Inner Thermal Printer
Display
110mm*60mm LCD Display
Storage
Automatical Save 1500 Tests
Parameters
K+, Na+, Cl-, Ca2+ ,pH,
Power Requirement
220 AV±10%, 50/60Hz,60W
Transport Package
Standard Exporting Wooden Case
Specification
CE SGS ISO13485
Trademark
HEPOBIO
Origin
Zhengzhou China
Production Capacity
5000 Per/Month

Product Description


HP-ELECTRO1000 Electrolyte Analyzer
Russian Hot Selling Medical Lab Automated Blood Gas Electrolyte Analyzer
Main Parameters:
1.It can measure the concentrations of K+, Na+ , Cl- and Ca++ and pH values.
2.Applies ISE (Ion Selection Electrode), which gives the instrument the advantages of minimum maintenance, easy assembly and disassembly, as well as stable and reliable measurements.
3.Working Modes:Normal mode: automatic calibration; this mode adapts to large and middle scale hospital with large sample volume; sleep functions which can save reagent.
Saving mode: 24 hours reagents consumption is only 7ml when it does not measure. This mode adapts to hospital with small sample volume.
4.Each test channel can be closed separately, So it is convenient to do emergencymeasurement.
5. 110mm×60mm LCD display, automatic screensaver, friendly interface, easy to operate.
6. Mini thermal printer can print repeatedly at any moment. It is convenient to feed paper. And the print is very clear.
7. Revising datas automatically to ensure the accuracy of data.
8. It can save1500 test results, data will not be lost even if the power is cut off. Users can inquire or print at any moment.
9. The instrument is equipped with a RS232 serial port, which can be connected to computer. It may collect, manage and print measure result by relevant software.
10. It has electrode-checking function. Users can do corresponding maintenance according to checking result
11. Exempt of routine maintenance, this greatly lighten the burden of operators; In-side software self-checking can suggest users eliminate the malfunction in time.
12. Advanced and reliable fluid position examination technology can save reagent
13. Adopt built-in operating system leads to a reliable performance. Users can modify each setting to meet different requirements
14. The quality-control inspecting function can track the accuracy of
the instrument.
 
 

Test items and specification:
 
Test Object Linearity Repeatability(Cv) Stability Accuracy  
K+ ±0.3mmol/L ≤1.0 % ±0.2mmol/L/h ±0.3mmol/L  
Na+ ±3.0mmol/L ≤1.0 % ±2.0mmol/L/h ±3.0mmol/L  
Cl- ±3.0mmol/L ≤1.0 % ±2.0mmol/L/h ±3.0mmol/L  
Ca++ ±0.2mmol/L ≤2.0 % ±0.2mmol/L/h ±0.2mmol/L  
pH -- ≤1.0 % ±0.02/h    
Standard Ca++ and Total Ca++(calculating value)  
Sample: Serum, Whole Blood, Plasma, Diluted Urine
Sample Volume: 90ul
Testing Time: ≤50s
Temperature: 10ºC-30ºC, humidity: ≤85%
Power Supply Voltage: AC160V-245V 50±1Hz
 
Reagents : 1. Calibration solution 500ml×3
                     2. Slop solution 500ml
                     3. Saturated KCLsolution 10ml
                     4. Protein-removing solution 5ml
                     5. Electrode solution 10ml
 

Technical Specification :
a.Technology : Apply advanced ISE technology
b.Measurement of Tco2 by pressure method
c.Sample : Serum / Plasma / Whole Blood /Urine
d.Sample Volume:90 ul
e.Reagent Volume:0.3 ml
f.Throughput : More than 60 samples / hour, ≤50 second per sample
g.Printer : High Speed inner thermal printer
h.Display : 110mm*60mm LCD display
i.Storage : Automatical save 1500 tests
j.Interface :Equiped with a RS232 communication, via this the instrument can transfer its saved data to the connected computer system.Collect, manager and print the patient data via corresponding PC suit .
k.Parameters:K+,  Na+,  Cl-,  Ca2+ ,PH,
Power Requirement : 220 AV±10%, 50/60HZ,60W
 
Use cost of HP-ELECTRO1000 Electrolyte Analyzer (2016 price)
Item Consumable Quantity Price(USD) Number of Users(10 people per day) Number of Users(30 people per day) Per capita cost
1 Calibration Solution 3 bottles (500ml/bottle) $33.8 150 Samples 360 Samples Calculated in accordance with 10 persons per day, the per capita cost is USD 0.35
2 Slope Solution 1 bottle (250ml/bottle) $10.4 1000 Samples 2800 Samples
3 Ion Electrode inner filled solution 1 bottle (10ml/bottle) $3.9 50 Samples 50 Samples
4 Reference Electrode Inner filled Solution 1 bottle (10ml/bottle) $2.6 1800 Samples 5400 Samples
5 Deproteinization Solution   1 bottle (10ml/bottle) $2.6 1800 Samples 5400 Samples Calculated in accordance with 30 persons per day, the per capita cost is USD 0.18,
6 ISE Electrodes 6 pcs(Na, K, Cl, pH, iCa and reference) $348 1800 Samples 5400 Samples
7 Printing Paper 1 roll $1.3 100 Samples 100 Samples
8 Other Consumables 1 set $0.013 1 Samples 1 Samples
9 Remarks Calculated in accordance with Commonly used model, instrument is not shutdown, sleep time set to 12 hours, the wash settings to factory default values.
Any changes will affect the cost of accounting
In addition, consumption of different instruments themselves have a certain bias, thus use and the cost will be some deviation
             
Consumables usage of HP-ELECTRO1000 Electrolyte Analyzer
Item Sequence Calibration Solution (ml) Slope Solution  (ml) Deproteinization Solution(ml) Frequency of use Remark
1 Automatic washing 0.02 None None 4 minutes per time  
2 A Measuring 0.5 None None According to sample size  
3 One-point Calibration 0.5 None None The default 15-minute per time  
4 Two-point Calibration 1.4 0.4 None The default 2 hours per time  
5 Electrode cleaning 0.5 None 0.2 Cleaned once every 30 samples  
6 Ion Electrode inner filled solution and Reference Electrode Inner filled Solution are only used once  the electrode Failure to use , generally do not use them . Generally do not use  
7 Blank          
 Russian Hot Selling Medical Lab Automated Blood Gas Electrolyte Analyzer
Russian Hot Selling Medical Lab Automated Blood Gas Electrolyte AnalyzerRussian Hot Selling Medical Lab Automated Blood Gas Electrolyte Analyzer

 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More