Customization: | Available |
---|---|
Classification: | Biological Diagnostics |
Type: | Biochemistry Analyzer |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1.Precise sample and reagent aspiration |
2.Built in bubble elimination prior to washing |
3.High pressure interior probe wash |
4.Carry-over<0.05% |
1.Light-spot Flatting Technology facilitates lower reaction volume |
2.24 hour non-stop refrigeration at 4-10ºC |
3.Minimum sample volume:2ul |
4.Reagent volume:20-25ul |
5.Minimum cuvette volume:150ul |
1.Front loaded reagent compartment for easier access |
2.Easy access for routine maintenance and troubleshooting |
3.Easy to connect pipeline and cable |
1.Real-time analytical and carousel status monitoring |
1.Levy-Jennings chart and Twin-plot chart |
2.QC Out-of-Range real-time alarm |
1.Historic date recall from reagent/calibrator/control archive |
2.Intuitive software,easy historical results |
1.User-defined customizable reflexive assays |
2.Multiple reflexive criteria may apply to a single assay |
3.A single reflexive criteria may apply up to 20 assays |
System Function | |
Fully automated,discrete,random access,STAT,urine and homogeneous immunoassays,STAT sample priority | |
Throughput | Constant 300 tests/hour,Massuring principles:Absorbance Photometry,Turbidometry |
Methodology | End-point,Fixed-time,Kinetic,Single/uual/Triple/Quadruple reagent chemistries,Monochromatic/Bichromatic |
Programming | User defined profiles and calculation chemistries |
Sample Handling | |
Sample tray | 120 positions for sample primary or secondary tubes and sample cups |
Sample volume | 2~100ul,step by 0.1ul |
Sample probe | Liquid level detection,clot detection and collision protection |
Probe cleaning | Interior and exterior automatic probe washing carry-over<0.05% |
Reagent Handling | |
Reagent tray | 80 positions in refrigerated compartment (4~10ºC) |
Reagent volume | R1:150~300ul,R2:20~150ul |
Reagent probe | Liquid level detection, collision protection and inventory check |
Probe cleaning | Interior and exterior automatic probe washing |
Reaction System | |
Reagent rotor | Rotating tray,81 cuvettes with automatic washing |
Cuvette | Optical length 5mm |
Reaction volume | 150~450ul |
Operating temperature | 37ºC |
Temperature fluctuation | ±0.1ºC |
Mixing system | 2 independent mixers |
Optical System | |
Light Source | Halogen-tungsten lamp |
Photometer | Reversed optics photometry |
Wavelength | 340nm 405nm 450nm 510nm 546nm 578nm 630nm 670nm |
Absorbance range | 0~4.0Abs(10mm conversion) |
Resolution | 0.0001Abs |
Control and Calibration | |
Calibration mode | Linear(one-point,two-point and multi-point),Logit-Log 5p,Spline,Factor |
Operation Unit | |
Operation system | Windows XP SP2 or SP3/ Windows 7 Home Basic |
Interface | RS-232 |
Working Conditions | |
Power Supply | 200~240V 50/60HZ 1000W or 100~120V 60HZ 1000W |
Temperature | 15~30ºC |
Humidity | 35~85% |
Water consumption | 18L/hour,De-ionized water |
Dimension | 912mm*721mm*570mm(W*D*H) |
HP-CHEM300H Automatic Chemistry Analyzer |
Specifications | |
Analyze Unit | ||
Throughput | Constant 3000T/h (non-ISE) | |
Theory | Absorption spectrometry, transmission turbidimetry | |
Methodology | End-point \Fixed-time\Kinetic\Ion selective electrode | |
Test according set up, random access | ||
Reaction plate | Contain 120 reaction cuvettes | |
Maximum reaction time | 15 minutes | |
Minimum reaction volume | 150 ul | |
Material of cuvettes | Special UV-transparent optical glass | |
Cuvettes use | Automatically cuvettes washing | |
Optical Unit | ||
Light Source | Halogen-tungsten lamp | |
Photometer | Reversed optics | |
Wavelength | 340nm-670nm wavelength option | |
Absorption | 0-4.0 Abs(10mn conversion) | |
Reagent Unit | ||
Reagent plate | 80 reagent positions ,support for single and double reagent, reagent completely open | |
Reagent storage temperature | 4~10 degree | |
Reagent bottle | 15ml, 20ml, 30ml, 50ml or 70ml ,dead volume is less than 1.0 ml | |
Reagent volume | R1:150-300 ul,R2:20-150ul step by 1.0 ul | |
Reagent/Sample Probe | Automatically checked ;Patent technology liquid level detection;Collision protection probe cleaning:Automatic washing for both inside and outside. | |
Sample Unit | ||
Sample plate | 120 sample positions | |
Sample type | Human (animal) serum \plasma\urine etc. | |
Samples cup | Support one-off micro cups | |
Sample volume | 2-100 ul, step by 0.1 ul | |
Sample/reagent probe | Automatically checked ;Patent technology liquid level detection;Collision protection probe cleaning:Automatic washing for both inside and outside. | |
Temperature control Unit | ||
Heating method | Direct thermal solid thermostat closed | |
Temperature equilibrium time | <3 minutes | |
Reaction temperature | 37 ±0.1 degree | |
Temperature fluctuation | ±0.1 degree | |
Operation Unit | ||
Software | WindowsXP \2000 | |
Database | SQL Server | |
Data Storage | Automatic store & copy; No time and volume limit; Lifetime preservation | |
Print format | Can be set up, offer several standard format | |
Calibration mode | Linear curve type: Single-point linear, two-point linear and multi-point linear none linear; Curve type: Logistic-Log 4P,Logistic-Log5p,Spline,index automatically use best calibration curve and standard | |
Quality control methods : | Real time, within day & between day | |
Quality control diagram | L-J \cumulative\twin plot | |
Status display | Real time monitoring of reagent residual volume .Running status of reagent tray, samples tray | |
Adjustment | Dynamic and real time display of running status; Intelligent carry over settings to adjust test sequence; original reaction data record; Detail profile of alert messages | |
Setting | Operation permission setting, Item setting, cross pollution setting, cuvette blank setting | |
Others | ||
Water consumption : < 18L/h | Power Supply :AC 220V-240V 50/60Hz 1000W or 100V-200V 60HZ 1000W | |
Frequency :Maximum 600VA | Dimension :912mm×721mm×570mm | |
Net Weight : 60kg | Accessory :Software |
|