• Mozambique Medical Laboratory Chemistry and Biochemistry Analyzer

Mozambique Medical Laboratory Chemistry and Biochemistry Analyzer

Classification: Biochemical Apparatus
Type: Biochemistry Analyzer
Certification: CE, MSDS, ISO13485
Group: Middle-aged and Old
Range of Working Wavelength: 340nm~750nm
Print: Internal Print
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company, Group Corporation

Basic Info.

Model NO.
HP-CHEM2100S
Communication
RS232 Serial Port
Weight
9kg
Warm-up Time
10min
Input Power
160va
Stray Light
2.0ABS
Test Temperature
37c, 30c, 25c
Test Method
End-Point, Kinetic, Two-Point, Standard
Transport Package
Exporting Wooden Package
Specification
CE
Trademark
HEPOBIO
Origin
China
HS Code
9027809900
Production Capacity
3000 Sets Per Month

Product Description

Mozambique Medical Laboratory Chemistry and Biochemistry AnalyzerMozambique Medical Laboratory Chemistry and Biochemistry Analyzer
1. INTRODUCTION
HP-CHEM2100S Semi-automatic Biochemistry Analyzer is a high performance photometer and can be used in the clinic of hospitals, epidemic prevention stations and health protection stations for biochemical tests. The instrument has a dedicated keyboard that enables you to rapidly change functions and set parameters, which can be checked on the display without applying difficult commands. Display is a liquid crystal one with alphanumeric and graphic options. Setting and detecting operations are easy and straightforward.
 
2.FEATURES
a)The instrument has a 7-wavelength static photometric group with 340, 405, 492, 510, 546, 578, 630 nm filters. It can select working wavelength by itself;( Most 9 configurable filter)
b)The instrument can keep 100 programs and 200 tests in its memory. You can program parameters either beforehand or at current time based on your needs;
c)The instrument can detect by the means of absorbance, kinetics, terminal, two-point, standard curve, blank comparing pipe and factor;
d)The instrument can print detection report that makes it easy to analyses and persevere;
e)The instrument will auto-check first after it is switched on.
f)RS232 Communication which can connected to PC,thus can manage,collect and printe the data..Measured values can be transmitted to PC for futhur processing
Notice: We do not provide reagents, so you should buy them by yourselves. Be sure that the reagents you buy are biochemical reagents and enrolled in your country.
 
3.TECHNICAL SPECIFICATIONS
1. Technical Indicators
1 Range of working wavelength:   340nm~750nm;
2 Range of absorbance: 0.000~3.000A;
      Unit:nm
Wavelength range Center wavelength accuracy Half the width
340-750 ±3.0 ≤12
3 Linearity:≤1% ;
4 Repeatability:≤0.005Abs
5 Stability:≤0.01Abs;
6 Stray light:≥2.0Abs(340nm);
7 Cross pollution rate:≤1%(Aspiration volume 600ul);
8 Test temperature: 37ºC,30ºC,25ºC;
9Accuracy error of test temperature:±0.2ºC;
2 Other configuration
1. Print: Internal print
2. Communication: RS232 serial port;
3. Volume: 565×410×290mm;
4. Weight: 9Kg;
5. Fuse:φ5×20  2A   2
3 Work Conditions
Temperature: 10~30ºC;
Relative humidity: <=70%;
Power supply: 220×(1±10%)V, 50×(1±2%)Hz;
Input power: 160VA;
Warm-up time: 10min;
Keep away from strongly electromagnetic field; Avoid direct irradiation by strong light;
Avoid dust and shake. There must be no caustic gas such as hydrochloric acid in air; Pollution level 2, Power supply must be earthed perfectly. Transient over-voltage type  3 category.
 
 Mozambique Medical Laboratory Chemistry and Biochemistry AnalyzerMozambique Medical Laboratory Chemistry and Biochemistry AnalyzerMozambique Medical Laboratory Chemistry and Biochemistry Analyzer


 
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now