HP-AA560B1 Economical Clinical Anesthesia Apparatus
HP-AA560B1 is an economic style anesthesia apparatus equip with ventilator which can meet most regular operation demands.It has simply blood pressure parameters can be showed in the display.And clients can set another special blood pressure coordinate with it accordingly to save cost.
Main Advantages:
*The high-precision Vaporizer is designed with a stable concentration output, automatic compensation for pressure, temperature and flow rate. And it is available to choose one kind of gas from Halothane, Enflurane, Isoflurane, and Sevoflurane, ensuring a successful anesthesia operation.
*Reliable pneumatic transmission system.
*Economic and proper configuration of technologies, optional as required by the Customer.
*Modularized design and upgrading. Upgrading is available as required by the Customer.
Composition of Anesthesia
*Main body: High-strength engineering plastic rack, light,beautiful and corrosion resistant
*Scope of application: Adult, child
*Gas source: O2, N2O: 0.27~0.55MPa
*Flow meter: O2: 0.1~1.0L/min 1.1~10L/min
*Flow rate of rapid oxygen supply: 25~75L/min
*Low oxygen pressure alarm: There will be sound alarm when the oxygen
pressure < 0.2MPa
*Vaporizer: It has the function of automatic compensation based on pressure,temperature,and flow rate. The regulation range of evaporator concentration is 0~5 vol%.
Among Halothane,Enflurane,Isoflurane and Sevoflurane,one can be chosen for application as required by the customer.
*Respiratory circuit: Working mode: all-close, semi-close, semi-open releasing
pressure: 0.5~7 kPa
*Respiratory bellows: Bellows for adults, bellows for children
tidal volume range:0~1500 ml
Composition of Ventilator
*Display mode: High-definition 4.8" LCD screen display
*Ventilation mode: IPPV, MANUAL (Manual monitoring of tidal volume, ventilation volume, respiratory rate).
*Ventilation parameters:
Tidal volume: 50~1500ml
Rate: 4~80 bpm
I:E 2:1~1:4 Pressure range: 1.0~6.0 kPa
*Parameters for ventilation monitoring: Tidal volume,ventilation volume,IPPVrate,I/E,peak pressure of airway,inspiratory trigger pressure,pressure - time waveform.
Security Alarm System:
Airway pressure alarm: Upper limit setting range 1.0~6.0 kPa
Low limit setting range: 0.4~2.0 kPa
TV alarm: Upper limit setting range 0.5~2.0L
Low limit setting range: 0.02~1.0L
Sustained high-pressure alarm: It will give alarm when stress have consistently been higher than 2.5 kPa.
Suffocation alarm: It will give sound and light alarm if there is no tidal volume input in 15s.
Brief View:
Model |
HP-AA560B1 |
Display mode |
4.8" LCD screen |
Ventilation mode |
IPPV, MANUAL |
Power |
AC 220V±10% 50Hz±1Hz |
Net Weight |
50kgs |
Package Size |
690*680*1300mm
|
Note:One year quality guarantee and 24 hours phone service for all the products supplied.