• Medical Display 2.5-4.5MHz Multi-Frequency Convex Probe Ultrasound
  • Medical Display 2.5-4.5MHz Multi-Frequency Convex Probe Ultrasound
  • Medical Display 2.5-4.5MHz Multi-Frequency Convex Probe Ultrasound
  • Medical Display 2.5-4.5MHz Multi-Frequency Convex Probe Ultrasound
  • Medical Display 2.5-4.5MHz Multi-Frequency Convex Probe Ultrasound
  • Medical Display 2.5-4.5MHz Multi-Frequency Convex Probe Ultrasound

Medical Display 2.5-4.5MHz Multi-Frequency Convex Probe Ultrasound

Classification: Imaging Diagnostic Equipment
Type: Ultrasound Scanner
Certification: CE, EEC, ISO13485
Group: Middle-aged and Old
Main Power Supply: AC220V±22V , 50/60Hz
Pseudo Color: 7
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company, Group Corporation

Basic Info.

Model NO.
HP-UC800
Software
3D
Screen Size
15" LED Medical Display
Probe
Trans-Vaginal Probe Linear Probe Rectal Probe M
Transport Package
Exporting Packing
Specification
CE, ISO9001, SGS
Trademark
HEPOBIO
Origin
China
HS Code
9027809900
Production Capacity
2000-3000

Product Description

HP-UC800  Specification
Scanning mode: convex / linear / micro-convex
Probes: 128 elements convex probe,trans-vaginal probe, trans-rectal probe, high frequency linear probe
Monitor: 15 inch high resolution LED
Operation panel: user-friendly, convenient and flexible with back-lit silica gel keyboard & track ball operation......(for more plz contact!)
 Human body& Veterinary:  Abdomen, OB/GYN, Cardiology, Urology, Peripheral Vessel, Small parts etc.
*2.5-4.5MHz Multi-frequency convex probe
*3D workstation"
*5.5-7.5MHz High frequency Trans-vaginal probe 

*6.5-8.5MHz High frequency Linear probe

*6.5-8.5MHz High frequency rectal Linear Probe

Equipment profile 
  Appearance   
 Dimension: 600×917×1450mm
 Weight: 126kg 
 Display: LCD (15 and 17 inches for operation. See the Operating Manual in the LCD Packaging Box for LCD setting methods) 
  Power supply 
 Power: (AC) 220V±22V 50Hz±1Hz
 Input power: 350VA 
  Safety classification 
 
 
Protection against electric shock : Class I.
Degree of protection against electric shock: Type BF.
  Protection against harmful ingress of water:
IPX1    the probe cable:IPX1 
IPX7    the traducer of the probe:IPX7
  Scanning mode 
 Electronic linear, electronic convex
  Mode of display  
 Black-and-white image: B, 2B, 4B, right/left B|M, B|D, right/left PW(D), top/down PW(D), M, B mode local amplification, linear probe trapezoidal imaging, 3D reconstruction/real-time 3D imaging 
 Blood flow images: spectrum: B/BC, BC/B, B/D, B/C/D  CFM: B|C|D, B|C|M, B|C double real-time, PW(D)(D), CFM, CPA, CW
 Color Doppler: 
 Mode of display: energy, velocity, variance (in support of velocity variance), frequency, gain 
 Display control: the size and position of the sampling box are adjustable, the emitting angle of the linear probe is adjustable. 
 Spectral Doppler: 
 Sampling volume and position are adjustable 
PW(D) tracing supports maximum and average velocity. The threshold of the maximum velocity is adjustable. Scanning scope: above base-line, below base-line and entire scanning. 
PW(D) sound can be turned on or off, and can be regulated in volume. 
Velocity measuring: in support of maximum and minimum velocity 
 Parameters for control of blood flow color images: Doppler frequency, position and size of sampling box, base line, color gain, deflection angle, wall filter, accumulative number of times, etc. 
  Color depth of display  
 Continuously adjustable
  Focusing 
 Electronic focusing + sound lens focusing 
 Emission involves single focus, double focuses, triple focuses, and quadruple focuses 
 Continuously dynamic focusing in receiving 
 Formation of digital beam  
 Continuously dynamic focusing
 Dynamic aperture diameter 
 Weighted sum of reception delay 
 In support of semi-moment scanning, and ±10° linear reception deflection angle 
 Multi-beam processing
  Signal processing/Doppler sound 
 Dynamic wave filtering 
 Quadrature demodulation
 Total gain control
Composite gain technology: 8-section TGC and D-AGC. 
 Low-pass filter
 Secondary sampling 
 Acoustic output adjustment 
 Adjustable Doppler stereophonic acoustic output 
 Image processing   
 Dynamic scope variation and logarithmic compaction 
 Time filtering 
 Space filtering 
 Frame average 
 Fringe enhancement
 Gray scale variation 
 B|M- or M-mode scanning speed 
 Linear density control 
 Scanning angle/width control 
 Image optimization 
 Upward and downward Image flipping 
 Multi-angle image rotation
 Options for color gray-scale bar inversion
 Combined processing of tissue and flow images
 Resolution of black-and-white images: 1024×768×8 bits (256 gray-scale) 
 Resolution of color images: 8 bit×8 bit×8 bit color coding 
  Selection of specific images 
 Optimized items are available to choose from 
  Basic measuring and calculating functions 
 2D normal measurement: distances, angle, perimeter, area (ellipse and locus methods), volume, volume - 3-line method (length, width, height), histogram, cross-section chart 
 Basic M-Mode measurement: time, distance, heart rate, valve rate 
  Obstetric measurement  
 With 4 varieties of obstetric databases for reckoning gestation age  
3 non-editable versions: Asian, European and American, plus 1 editable version: user-customized.  
The gestation age can be reckoned by the information in each version on gestational sac diameter, crown-rump length, biparietal diameter, head circumference, abdominal circumference, femur length, humerus length, abdominal transversal diameter, length of vertebrae, occipital-frontal diameter, cerebellum diameter, fibula length, radius length, Cisterna Magna, inner orbital diameter, output orbital diameter, amniotic fluid index, fetal heart rate, nuchal transparency, distance and area, etc.  
 Obstetric report 
 Measurement and calculation of amniotic fluid index (AFI)  
 Ratio calculation (BPD/OFD, FL/AC, FL/BPD and HC/AC)
 Fetus weight estimation 
 Reckoning the gestation age and EDD by LMP and BBT
 Fetal biophysical score
 Fetal growth curve
  Andrology measurement and calculation 
 Measurement and calculation of prostate and testis 
 Calculation of predicted prostatic specific antigen (PPSA) and Prostatic Specific Antigen density (PSAD). 
  Gynaecology measurement 
 Measurement and calculation of the uterus, left ovarium, right ovarium, left folliculus, right folliculus, etc. 
  Urology measurement and calculation 
 Detection and calculation of the left kidney, right kidney, bladder, residual urinal vol, etc. 
  Vessel measurement and calculation 
 Measurement and calculation of area stenosis rate and vascular stenosis rate. 
  Multi-fetus detection and measurement 
 Detection of multiple fetuses 
  Small parts detection and calculation   
 Detection and calculation of thyroid, galactophore, masses, etc.  
  Orthopedic surgery measurement 
 Detection of the left and right hip joint 
 Cardiac detection and calculation functions 
 Cardiology measurement software package-contains features of analyzing and measuring aorta, mitral valve, (left/right) ventricles, etc.  
 Area stenosis percentage (% area sten), tube diameter stenosis percentage (% Diam Sten)  
 Body surface area (BSA) 
  Body mark   
 In terms of bodily function, an body mark database is divided into several parts: abdomen, andrology, cardiology, gynecology, musculoskeletal, obstetrics, pediatric, small parts, urology, etc. 
  Screen-displayed information  
 Probe conditions, mode of display, depth, focus, dynamic range, body marks, probe position marker, acoustic output, patient conditions, name of medical agency, measured value, time and date, scale, scanning direction, gray-scale curve, current working frequency of the probe, frame frequency, B-Mode total gains, C-Mode total gains, Mode-D total gains, menu, annotations, gray-scale belt, puncture guide line, TI (thermal index), MI (mechanical index)    
 Storage   
 Probe parameter storage  
 Image storage 
 Cine loop storage 
 Measurement results storage 
 Report storage 
  Cine loop 
 Automatic cine-loop 
 Manual cine-loop 
 Cine-loop speed setting  
 Cine-loop search
 Frame-by-frame forward/backward cine-loop 
  Digital ultrasonic working station (optional)  
 General report 
 Obstetric report 
 Andrology report 
Gynaecology report 
 Urology report 
 Blood vessel report 
 Small parts report 
 Cardiology report (ventricular report, mitral value report, aortic report, left ventricle report) 
 Search 
  Gray-scale  
 256 gray-scale  
  Language interface  
 Chinese and English available 
  Function of the trackball 
 Performing various operations based on the working state and menu
 Controlling multiple electronic scale, locating the cursor, completing measurement 
  Input/output port  
 VGA output port
 DVI output port 
 Network port 
 USB port 
 Video port 
Introduction to the probe 
 3.5MHzR65 multi-frequency convex probe    
The probes have a frequency range between 2.0MHz-5.5MHz. In the B-Mode , they have a scanning angle of 60°. In the M-Mode, they can activate particular array element as fixed-frequency probes. They can be used in the combination of B-Mode and M-Mode.
Scope of application: examination and diagnosis of abdominal tissues, such as liver, gallbladder, spleen, pancreas, kidneys, gastro-intestinal, uterus, urinary bladder, prostate, etc.; assessment of growth and maturity of fetus in obstetric diagnosis.  
 6.5MHzR10 multi-frequency convex probe  
The probes have a frequency range between 5.0MHz-9.0MHz. In the B-Mode , they have a scanning angle of 140-158°. In the M-Mode, they can activate particular array element as fixed-frequency probes. They can be used in the combination of B-Mode and M-Mode. 
Scope of application: vagina, uterus, rectum, rectum wall, prostata, etc. 
Warning: Oil- and bacteria-free rubber sleeve must be added when using the probes. The probes should not be activated until going in the patient's body. 
  7.5MHzL46 multi-frequency linear probe 
The probes have a frequency range between 6.0MHz-12.0MHz. In the B-Mode , they have a scanning width of 38-45. In the M-Mode, they can activate particular array element as fixed-frequency probes. They can be used in the combination of B-Mode and M-Mode.
Scope of application: newborns, musculoskeletal system, peripheral vessels, small parts (including breasts, thyroid, testis, etc.) 
 3.0MHzL19 multi-frequency phased-array probe
  The probes have a frequency range between 2.0MHz-5.5MHz. In the B-Mode , they have a scanning angle of 90°. In the M-Mode, they can activate particular array element as fixed-frequency probes. They can be used in the combination of B-Mode and M-Mode.
Scope of application: heart, abdominal tissues and parts   
 4.0MHzR40 multi-frequency convex volume probe
 The probes have a frequency range between 2.0MHz-5.5MHz. In the B-Mode , they have a scanning angle of 70°. In the M-Mode, they can activate particular array element as fixed-frequency probes. They can be used in the combination of B-Mode  and M-Mode.
Scope of application: real-time 3D scan; examination and diagnosis of fetus, abdominal tissues, uterus, etc.; assessment of growth and maturity of fetus in obstetric diagnosis.
Medical Display 2.5-4.5MHz Multi-Frequency Convex Probe UltrasoundMedical Display 2.5-4.5MHz Multi-Frequency Convex Probe UltrasoundMedical Display 2.5-4.5MHz Multi-Frequency Convex Probe UltrasoundMedical Display 2.5-4.5MHz Multi-Frequency Convex Probe UltrasoundMedical Display 2.5-4.5MHz Multi-Frequency Convex Probe UltrasoundMedical Display 2.5-4.5MHz Multi-Frequency Convex Probe Ultrasound

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now