Basic Info.

Model NO.
HP-Elisa9600
Wavelength Range
400nm~800nm
Measurement Range
0.001~3.000ABS
Repeatability
No More Than 0.5%
Stability
No More Than 0.005ABS
Linearity
<±1% (Test Scope Between 0.1~1.5)
Filters
405, 450, 492, 630nm (Single, Double Available)
Product Name
Microplate Reader
Name1
Clinical
Transport Package
Neutral Export Packing
Specification
CE, SGS
Trademark
HEPOBIO
Origin
China
HS Code
9027809900
Production Capacity
2000units/Momth

Product Description


HP-Elisa9600  Elisa Reader
America Popular Superior Quality Elisa Reader Machine
Packing Details: 650*495*350mm, 0.05CBM , NW:8KG, GW:10KG
 
Elisa Reader, 8 channels optical system, 5 secs/96 wells(single wavelength)-some are 6 secs, 10 secs /96 wells ,.7 secs/96wells(double wavelength )-some products are 20 s , 4 filters.
 
 
 
Specifications
Measurement System :  8-Channel optical system
Measurement Range :  0.000-4.000Abs 
Photometric Accuracy :  ±1% or ±0.001Abs
Repeatability :  <±0.3% 
Stability :  <0.002Abs 
Linearity :  <±0.5% 
 Reading Speed :  <5secs/96holes(single wavelength),
<7secs/96holes(double wavelength) 
Filters :  Standard: 4 filters (405, 450, 492,630 nm)  or other wavelength on request..Totally 10 filter can be installed.
Full One year Warranty 
 
 
 Characters:
The HP-ELISA9600 Microplate Reader is a semi automated bench top instrument focused on clinical immunity-test in hospitals or epidemic preventing stations. It has good characters such as high sensitivity, high accuracy, high speed of detection and the easiness of operation etc. Display is a liquid crystal one with alphanumeric and graphic options. Parameters can be checked on the display without using difficult command sequences.

 Main Functions:
The instrument is compatible with registered diagnostic EIA kit, primarily used in hospitals or some detection related to clinical immunology.
  

Function and Technical Specifications

1 Fundamental parameter
  1. Range of working wavelength :300nm-800nm; 
  2. Range of detection:0.000A -4.000A;
  3. Resolving power: 0.001 A;
  4. Filters when leaving factory: 405nm, 450nm, 492nm, 630 nm, with the maximum array of 10 filters between 300nm-800nm simultaneously.
  5. Reading speed: single wave 5s, dual wave 10s;
  6. Dimension: 420×325×210 mm(W*D*H)
  7. Weight: 10 kg
2 Technical Specifications
1)Characters of the filters
                                     Table 1: Characters of the Filters
Accuracy of  wavelength  (nm) Half-width(nm)
±3.0 ≤12
 
 
  1.  The errors of absorbance accuracy are as follows:
Table 2: Absorbance Accuracy
Absorbance (A) Accuracy Error
0.000-2.000 ±0.01
>2.000-3.000 ±0.05
>3.000-4.000 ±0.15
3)The Linearity Error are as follows:
Table 3: Linearity of the Instrument
Absorbance (A) Error (%)
0.000-2.000  ±1.0
>2.000-3.000 ±2.0
>3.000-4.000 ±5.0%
 
 
 
 
 
4) Reproducibility Error: ≤0.5%;
5) Stability Error: ≤±0.005A/10min;
3 Main functions
1) Provided with power on self-checking. Error data will display on LCD monitor if something wrong with the photoelectric system.
2)Filter choosing-mode: Automatically
3) Checking mode: Single wave/dual wave detection; single aperture /dual aperture detection
4) Input mode:Key in touch screen;
5) Input format: Impute capital letter/lowercase letter/number at random;
6)Item parameters: Provided with function of set/save/ inquiry 120 detection parameters, this is called in later usage.
7)Defection of calibration: with the function of calibration-defection,which can save/modify 120 parameters of calibration and curves.
8)Detecting method:Absorbance/qualitative/quantitative detection;
Qualitative test: single critical value checking; dual-critical value ,threshold level testing, gray-area setting;
Quantitative test:single point,parabolic interpolation, linear regression, semi-logarithm regression, logarithm regression, logit-log , enzyme kinetics, PCR testing;
9)Saving function:Save the checking results of 100 pieces of plates to be called in later usage.
10)Output mode:
Absorbance: display/printout originally absorbable value;
Qualitative checking: Display/printout absorbable value, critical value, S/CO, qualitative results;
Quantitative checking: Display/printout absorbable value, density, standard reference value,quantitative results.
11) QC function: Inquiry/printout the QC data and chart; 
12) Communication: Equipment with RS-232 interface.
13) With self-monitoring function(real-time)on each testing light-source signal channel.
14) With dormancy function on light-source lamp.


4.Specifications
Technical Specification
     ELISA microplate reader : Type:   HP-ELISA9600
  1.  Stand-alone microprocessor controlled photometer designed to measure absorbance in 96 well (12X8) microplates. Yes
 
  2.  Programmable reading between 1 to 96 wells Yes
  3. Reading time: single wave 5s/96 plate, dual wave 7s/96 plate; Yes
  4.  Reading Domain: up to 4.0 OD in range 400 - 850 nm Yes
  5.  Dynamic range: 0 to 4.000 OD Yes
  6. Linearity: < ±0.5% from 0 - 3.500 OD Yes
  7.  Precision: 0 to 3.500 OD: ±1% or ±0.001 Abs CV max Yes
  8.  Wavelength range: 400-800 nm Yes
  9.  Light source: Tungsten halogen lamp Yes
  10.   Filters: up to 6 changeable filters (on board to be delivered with at least 450 nm, 490 nm, 620 nm) Yes
  11.  Capacity: 120 assay procedure, 100 plates, and 20 standard curve data (for quantitative determination) Yes
  12. Result interpretation: Positive, negative, doubtful Yes
  13. Plate validation: up to 6different criteria, possibility of exclusion of nonconforming values and reinterpretation of the results Yes
  14.  Results printing: exactly data, and Negative ,Positive Yes
  15.  Self test Yes
  16.  LCD display Yes
  17.  Power: 220-240 V 50/60 Hz Yes
  18. Printer interface: (to be delivered with printer) With Inner heat printer or external printer,all is ok
  19.  Computer interface Yes  RS232 interface
20 .If you need, we also can supply Laser, printer   Yes ( We can give a Laser printer for this machine
)
  20.1.Compatible with "ELISA Microplate automated reader"   Yes
  20.2.  A4 paper format  
  20.3.  Spare cartridge -1 Yes
  20.4.  Printing speed not less then 3 ppm  Yes
  20.5.  Compatible MS Windows Yes
  20.6.  - Workload - 1000 pages per month, Printer resource - 20 000 hours Yes
  20.7. Power source -220 v Yes
General Conditions  
  1. The installation is so simple that operators can install it by themselves according to the user manual.
2. HEPO INTERNATIONAL will provide the customers with free training service in our factory.The traffic and accommodation charge will be on the customers' account.
Also, HEPO INTERNATIONAL will provide free technical support via e-mail, fax or telephone at any moment.
3. Full warranty - 1 years
4. Technical documentation in English  Full One year Warranty
 
America Popular Superior Quality Elisa Reader Machine
America Popular Superior Quality Elisa Reader Machine

America Popular Superior Quality Elisa Reader Machine
SERVICES
Direct sales, OEM, Training, Installation
 

Please let us know your specific request. We would like to recommend you the most suitable model based on your information.  

America Popular Superior Quality Elisa Reader MachineAmerica Popular Superior Quality Elisa Reader Machine

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now