High End Full Automatic Electrical Interlocking High Pressure Steam Sterilizer

Theory: Autoclave
Type: Pressure Steam Sterilization Equipments
Certification: CE, SGS, ISO13485
Electric Tension: 220V
LCD Display: With LCD Display
Ultra High Temperature Alarm: Ultra High Temperature Alarm
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company, Group Corporation

Basic Info.

Model NO.
MJ-54A
Sterilization Information Recording and Printing
Sterilization Information Recording and Printing
Material
Stainless Steel
Internal * Diameter
370*508mm
Volume in Liters(L)
54
Material of Inner Container
SUS304
Operation Model
a. Sterilizing; B. Sterilizing-Keeping Warm; C. M
Exhaust Way
All Exhaust,Micro Exhaust,No Exhaust
Transport Package
Stardard Exporter Package
Specification
700*510*730
Trademark
HEPOBIO
Origin
China
Production Capacity
2000 Sets Per Month

Product Description

High End Full Automatic Electrical Interlocking High Pressure Steam SterilizerOur full automaticity autoclave is high pressure steam sterilizing style with automaticity .It can be widely used for disinfection,sterilization and dissolution medium in hospitals,research institutes and the lab,etc.

Choosing Reasons:1,International Famouse Brand Autoclave;2,Full Auto Style,True Electrical interlocking safety system;3,Much Safety and Steady in this line;4,One unit order accepted;5,7Days delivery time ok!

Advantage Functions:

 1)The system is designed with the self-checking function of safety status. Pot cover can not be opened when the electricity is cut off.
 2)The system is designed with the safe startup temperature and pressure self-sensing joint lock device. When the temperature in the sterilization cavity is below 80ºC, and the pressure in the cavity is zero, pot cover can be opened. Otherwise, locking institution will automatically lock the pot in case of any accidents arising from improper operations, such as scald and scorching.
 3)Over-temperature protection: high-precision temperature sensor and over-temperature protection control system guarantee that the system will stop heating and give an alarm when the temperature is abnormal. In addition, mechanical over-temperature protector possesses the double over-temperature protection functions.
 4)Over-pressure protection: high-precision pressure sensor and over-pressure protection system guarantee that the system will open the valve to release the pressure and give an alarm when the temperature is abnormal.The other,mechanical pressure safety valve possesses the double over-voltage protection functions. 
 5)Protection against dry burning: when there is a lack of water for sterilization, the system will assume that the heater is abnormal, and automatically stop the operation of the heater.


Intelligence Autoclave:
 1)Self-checking system: be able to check the quality of sensor, whether there is short circuit or open circuit, and whether the chip of control panel is damaged or not. In the case of wrong operation or failure, it will display failure code to remind users.
 2)Zero pollution of exhaust: possess two gas collecting bottles. Sterilization steam is condensed for two times to ensure zero exhaust of steam, thus preventing sterilization steam from entering the lab and polluting the environment.
 3) Intelligent computer control system not only realizes the fully automatic control of the sterilization process, but also makes sterilization safer and more repeatable.
 4)Four preset sterilization modes are designed for solid samples, liquid samples, and agar.
 5)Memory storage system: users can set their own sterilization parameters.
 6)Saturated steam detection:The system automatically detects the exhaust of cool air to produce the sterilization environment of pure steam and further guarantee the optimum sterilization effect.
 7) Automatic exhaust control: possess the modes of full exhaust, micro-exhaust, and non-exhaust so as to meet sterilization requirements of various samples.
 8)Timing startup function: preset the timing program (1-99 hours) to enable the sterilizer to automatically start up the sterilization according to the preset time.

Interface control Systems
 1)Automatically display the latest sterilization program after the startup. Start up the sterilizer with the click of the START button.
 2)Possess status flow chart, showing the current sterilization mode, sterilization status, and completed sterilization program. Programs to be processed are designed with the countdown function, making the residual time extremely clear.
 16)Users can inquire concrete parameters of the current program with the click of the CONFIRM button.
 Optional Items:Article temperature sensor, printing function.
 
 


Note:One year quality guarantee and 24 hours phone service for all the products supplied.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now