5.0kw High Frequency with C-Arm System

Classification: Imaging Diagnostic Equipment
Type: X Ray Equipment
Certification: CE, SGS, ISO13485
Group: Middle-aged and Old
Fixed Anode Dual-Focus: Large Focus: 1.: Forward and Backward Movement: 200mm
Inverter Frequency : 40kHz: Thermal Capacity : 35kj (47khu)
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company, Group Corporation

Basic Info.

Model NO.
HP-PLX112E
Manual Fluoroscopy : Continuous
Max Rated Capacity : 5 Kw
Tube Current : 0.3m
Automatic Fluoroscopy : Tube Voltage:40kv~12
Max Rated Capacity : Tube Cu
N.W. 353kg
G.W.538kg
Packing Details: 2440mm×1100mm×1420mm
Max Rated Capacity: 3.5 Kw
Continuous Tube Current 4.1mA~8mA
Tube Current : 0.3mA~4mA Set Manually
Automatic Fluoroscopy: Tube Voltage:40kv~110kv Ad
Transport Package
Wooden Case
Specification
CERTIFICATES: CE, ISO13485, ISO9001
Trademark
HepoMed
Origin
China
Production Capacity
500 Pieces/Month

Product Description

HP-PLX112E High Frequency Mobile C-arm System (5.0KW, 100mA)
                            
Packing Details            : 2440mm×1100mm×1420mm ; 3.9 CBM
                                N.W. 353KG      G.W.538KG

Specifications
1.Fluoroscopic Capacity
   Max rated capacity             : Tube Current 4mA, Tube Voltage 120kV
   Automatic Fluoroscopy      : Tube Voltage:40kV~120kV Adjust  Automatically
   Tube Current                      : 0.3mA~4mA set manually
   Manual Fluoroscopy          : Continuous Tube Voltage:40kV~120kV
   Continuous Tube Current  : 0.3mA~4mA
   Pulse Fluoroscopy             : Continuous Tube Voltage 40kV~120kV
                                                   Continuous Tube Current 4.1mA~8mA
2. Photography Capacity
   Max rated capacity             :  5 KW
   Tube Voltage and Current Combination :   40kV~49kV   1 ~180 mAs
                                                  50kV~59kV   1 ~140 mAs
                                                  60kV~69kV   1 ~125  mAs
                                                  70kV~79kV   1 ~110 mAs
                                                  80kV~89kV   1 ~100 mAs
                                                  90kV~99kV   1 ~80  mAs
                                                  100kV~109kV 1 ~63  mAs
110kV~120kV 1 ~50  mAs
   Plate holder Size  :  200mm×250mm(8″×10″)or  250mm×300mm(10″×12″)
3.X-ray Tube
   X-ray Tube Special for High Frequency
Fixed anode  Dual-focus: large focus: 1.5, small focus: 0.3( Advantage)
Inverter Frequency       :  40KHz
Thermal capacity        :  35KJ (47KHU)
4.Video System
   Image Intensifier                : Image Intensifier made by TOSHIBA (9″, 6″,4.5″)
  CCD Vidicon                      : Ultra low-light CCD camera imported from Japan
  Monitor                                 : Horizontal 1000 lines and vertical       800 lines,  Bandwidth : 12.5MHz,  Image/sec : 75
  CCU(central control)           : Recursive Filter: K=8,8 images storage,  image upright, image overturn,positive &  negative image;LIH(last Image Hold, and OSD(monitor display)
5.Structure:
Directive wheel  : ±90°revolution,can freely change the moving direction of the unit .
Ascending & Descending Range of Pillar  : ≥400mm
C-arm                                   : Forward and Backward Movement: 200mm
                                                Revolution around Horizontal Axis:  ±180°
                                                Revolution around Vertical Axis     :  ±15° (Advantage), better than others'  ±12.5°, easier  to take special positions radiography )
                                                Slip on orbit: 120°(+90°~ -30°)
I Usage:
Orthopaedics: osteopathy, diaplasis, nailing
Surgery: removing foreign body, cardiac catheter, implanting pace maker, interventional therapy, partial radiography, local photography, and other work.

II Features
1. New integrated design, compact appearance, convenient operation.;
2. Unique hand-held remote controller, more convenient operation
3. Graphical colorfully LCD touch screen console interface, convenient operation, fashionable design
4. High-quality combined HF-HV X-ray generator, greatly reducing the X-ray irradiation.
5. Toshiba image intensifier is employed, stable and reliable in quality, high-definition image and display system
6. With the perspective KV, MA automatic tracking feature, the image brightness and definition are automatically set at optimal function.
7. Medical high-resolution progressive output TV system, eight image storage, clearer image and convenient operation.

III Configuration
1, New (with electric auxiliary support arm) C-arm main rack     one set
2, High-frequency high-voltage X-ray generator and high-frequency inverter power supply(5.0KW,40KHZ,120KV)                                                    one set
3, Toshiba 9-inch image intensifier                            one set
4, 1 million pixel ultra-low-light digital cameras                  one set
5, high- definition progressive output CCU main-control system   one set
6, High-thickness grids                                         one set
7, Electric adjustable collimator                               one set
8, 14-inch high- definition medical monitor                      one set
9, Unique hand-held remote controller                         one set

IV System Performance and Parameter
Category Project Content





Electrical
Performance
Photography Capacity 5.0KW
Fluoroscopy Capacity Tube current:8mA  Tube Voltage:120KV
Automatic Fluoroscopy Tube Voltage:40kV~120kV automatical adjustment
Tube Current:0.3mA~4mA automatical adjustment
Manual Fluoroscopy Tube Voltage:40kV~120kV Continuous
Tube Current:0.3mA~4mA Continuous
Pulse Fluoroscopy Tube Voltage:40kV~120kV Continuous
Tube Current:4.1mA~8mA Continuous
Photography Tube Voltage and mAs 40 kV~120 kV   20-100mA  1-180mAs
film holder Size 200mm×250mm(8″×10″)or
250mm×300mm(10″×12″)
X-ray Tube X-ray Tube Special for High Frequency Fixed anode   Dual-focus, small focus: 0.3, large focus:1.5 High Frequency Inverter: 40KHz thermal capacity 35KJ (47KHU) Tube thermal capacity 650KJ(867KHU)
Video
System
Image Intensifier TOSHIBA (9″) Image Intensifier
CCD Video camera Ultra low-light CCD camera
Monitor Horizontal center resolution 1000/L, frequency for picture refresh is 75HZ
CCU main control High Definition progressive output mode, 8 level Noise Reduction,8 image storage, Vertical Image, Horizontal image flip, positive or negative image
Structure Directive wheel and major wheel Directive wheel 360° rotation, freely change the moving direction of the unit, major wheel ±90° rotation
C-arm Electrical Ascending & Descend ≥400mm
Monitor rotation 135°
Forward and Backward Movement: 200mm
Rotation around Horizontal Axis:  ±180°
Rotation around Vertical Axis     :  ±15°
Focus screen distance:960mm C-arm opening: 760mm
C-arm arc depth: 640mm  Slip on orbit: 120°(+90°~ -30°)