Gold Member Since 2014
Audited Supplier
Zhengzhou Hepo International Trading Co., Ltd.

Elisa Reader, Urine Analyzer, Biochemistry Analyzer manufacturer / supplier in China, offering 7.5" Touch Screen Large Capacity Lab Elisa Reader (HP-Elisa9606), Saving Energy Style Ultra Low Temperature Deep Freezer, Digital Display Upright -86 Degree Deep Freezer (160L) and so on.

(/ )

Supplier Homepage Product Clinical Analyzer Chemistry Analyzer 7.5" Touch Screen Large Capacity Lab Elisa Reader (HP-Elisa9606)

7.5" Touch Screen Large Capacity Lab Elisa Reader (HP-Elisa9606)

Purchase Qty.:
(Pieces)
1 2-4 5+
FOB Unit Price: US $3,000 US $2,500 US $1,500
Purchase Qty. (Pieces) FOB Unit Price
1 US $3,000
2-4 US $2,500
5+ US $1,500
Get Latest Price
Production Capacity: 200units/Momth
Transport Package: Neutral Export Packing
Payment Terms: L/C, T/T, Western Union, Paypal, Money Gram

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: HP-Elisa9606
  • Type: Biochemistry Analyzer
  • Group: Middle-aged and Old
  • Measurement System: 8-Channel Optical System
  • Measurement Range: 0.001~3.000ABS
  • Stability: No More Than 0.005ABS
  • Filters: 405,450,492,630nm (Single, Double Available)
  • Specification: CE, SGS
  • HS Code: 9027809900
  • Classification: Biological Diagnostics
  • Certification: CE, SGS, ISO13485
  • Model: HP-Elisa9606
  • Wavelength Range: 400nm~800nm;
  • Repeatability: No More Than 0.5%
  • Linearity: <±1% (Test Scope Between 0.1~1.5)
  • Trademark: HEPOBIO
  • Origin: China
Product Description

HP-Elisa9606 elisa reader is a medical instrument in laboratory,mainly used to immunity detection and microanalysis in chemistry and biochemistry in hospital and relevant clinical laboratory.It adopts photoelectric colorimetry with ELISA reagent to test. It tests the absorbance of standard liquid and detecting liquid firstly, and set out the content of detecting substance in sample liquid through analysis and calculation.
According to IEC 61010-1,its safe classification belongs to I kind, and according to IVDD 98/79/EC, its product classification belongs to others. It can work continually, and displays in big screen. Its programme and test operation are man-machine conversation.

Main Structure:
The instrument has two main components: the mainframe and the printer.
The mainframe is composed of optic system, 8-channel detection system, singlechip system and enzymatic plate driving system.

Main Functions:
1) Main functions for HP-Elisa9606microplate reader:
a. Instrument can do self-check in boot-strap.
b. Instrument can select filter automatically.
c. Instrument has the function of vibration.
d. Instrument can communicate and it has two protocols to choose.
e. Instrument can store 126 test-programs, which can be called in test.
f. Instrument can store 126 groups of calibrating parameters and curve, and it also can store 105 groups of testing data for full-plate.
g. Instrument has single and dual wavelength test to be selected by user.
h. Instrument has the analysis function of absorbance, qualitative and quantitative. Thereinto qualitative test has two methods, which respectively is critical value and critical value adjustment, and you can setup the area of gray scale at will; the quantitative test has nine methods, which respectively is linear regression, semi-logarithm, full-logarithm, exponential regression, ratio regression, quadratic equation, point to point, ratio semi-logarithm and Logit-log curve.
i. Instrument can output ten kinds data, which is respectively absorbance, critical value, feminine and masculine result, semi-quantitative value, concentration, normal reference value, judgment result, QC data, QC drawing and calibrating curve.
j. Instrument can randomly store, inquire and print the QC data and QC curve in month for five items.
2) The main functions of microplate reader for DNM-9606, DNM-9606A, DNM-9606B, DNM-9606C, DNM-9606D, DNM-9606E is as follows:
a. Instrument can do self-check in boot-strap.
b. Instrument can select filter automatically.
c. Instrument has the function of vibration.
d. Instrument can communicate and it has two protocols to choose.
e. Instrument can store 126 test-programs, which can be called in test.
f. Instrument can store 126 groups of calibrating parameters and curve, and it also can store 105 groups of testing data for full-plate.
g. Instrument has single and dual wavelength test to be selected by user.
h. Instrument has the analysis function of absorbance, qualitative and quantitative. Thereinto qualitative test has two methods, which respectively is critical value and critical value adjustment, and you can setup the area of gray scale at will; the quantitative test has nine methods, which respectively is linear regression, semi-logarithm, full-logarithm, exponential regression, ratio regression, quadratic equation, point to point, ratio semi-logarithm and Logit-log curve.
i. Instrument can output ten kinds data, which is respectively absorbance, critical value, feminine and masculine result, semi-quantitative value, concentration, normal reference value, judgment result, QC data, QC drawing and calibrating curve.
j. Instrument can randomly store, inquire and print the QC data and QC curve in month for five items.

Main Parameters:

Model

HP-Elisa9606

Measurement System

8-Channel optical system

Wavelength Range

400nm~800nm;

Measurement Range

0.001~3.000Abs

Photometric Accuracy

±1.0% or ±0.01(test scope between0.1~1.5)

Repeatability :

no more than 0.5%

Stability :

No more than 0.005Abs

Linearity :

<±1% (test scope between 0.1~1.5)

Filters :

405,450,492,630nm (single, double available)

More information for our products and service,please turn to our official website or contact us directly
Product Groups
Send your message to this supplier
Avatar
Mr. Shuang Zhao
Project Manager
*From:
To: Mr. Shuang Zhao
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now