Material: Stainless Steel
Type: Side Bench
Usage: Hospital, School, Company, Research Institute
Color: Grey
Customized: Customized
Condition: New
Samples:
US$ 2650/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company, Group Corporation

Basic Info.

Model NO.
HP-LFC1100H
External Size (W X D X H)
1060*800*1690
Internal Size (W X D X H)
980*500*600
Work Surface Height
700mm
Display
LED
Pre-Filter
Polyester Fiber, Washable
Airflow Velocity
Average of 0.3~0.5m/S
Noise
< 60 Db
Fluorescent Lamp
21W*1
UV Lamp
20W*1
Consumption
320W
Transport Package
Export Packing
Specification
One person Operation
Trademark
HEPOBIO
Origin
Zhengzhou City of Henan Province
HS Code
841480
Production Capacity
1000set Per Month

Product Description

Laminar Flow Cabinet
Laminar Air flow Clean bench can supply you the high cleanliness and germfree laminar air flow surroundings.All the operation are under constant positive pressure in order to prevent the infiltration of contaminated room air. The air flow can be horizontal flow and vertical laminar flow.
BBS Series Laminar Air Flow Cabinet (BBS-H1100)
Main Advantages
1, HEPA Filter with high efficiency of 99.999% at 0.3um.
2, Microprocessor control system,LED/LCD display.
3, Air Speed Adjustable.
4, UV timer for BBS-H1300/H1800/V1300/V1800.

Main Parameters:
Model HP-LFC1100H HP-LFC1500H HP--LFC1300H HP-LFC1800H
External Size
(W x D x H)
1100*808*1690 1500*808*1690 1300*825*2040 1800*825*2040
Internal Size
(W x D x H)
1000*500*600 1400*500*600 1200*500*570 1700*500*570
Work Surface Height 750mm 750
Display LCD LCD
Material Main Body Cold-rolled steel with anti-bacteria powder coating
Work Table 304 stainless steel
Side And Front Window 5 mm toughened glass, anti-ultraviolet radiation
Pre-Filter Polyester fiber, Washable
HEPA Filter Efficiency ≥ 99.999 % at 0.3 μ m
Airflow Velocity Average of 0.3~0.5m/s
Noise < 60 dB
Fluorescent Lamp 12W*1 16W*1 12W*1 16W*1
UV Lamp 20W*1 30W*1 30W*1 30W*1
Consumption 200W 300W 400W 500W
Caster Universal Wheel with leveling feet
Power Supply 110/220V ± 10%; 50/60HZ
Standard Accessory Fluorescent Lamp,UV Lamp*2,Base Stand,Waterproof Socket*2

After Sale and Complaint
1.After-sale Service Policy
 1)All our products are one year quality guarantee time generally.Longer guarantee can be refer to detailed offer. 
 2)We will supply spare parts supports for most of our products for 5 years at least,and we will inform updated information for products supplied or stop production to our agent and showed them in our official website.
 3) If any quality problems such as design, manufacture, function or procedure occur within the guarantee period,we will in charge to maintain or supply spare parts for the equipment in reasonable ways or replacement the equipment if it certified to be needed.
 4)The cost for spare parts is free and labor is free too within guarantee period.And it will be charged by reasonable price out of guarantee period.The delivery fees,traffic frees and subsistence fees are charged accordingly or supplied by your side within and out of guarantee time.
 5)The primary positive response should be supplied through phone or email or other reasonable ways within 24 hours after getting the notice from agent or end users.And the details settlement program should be supplied by paper or email in days no more than 6 working days after getting the After-sale support from.
 6)We will provide a lifetime paid maintenance service and technical support for all our products out of guarantee period.And we will inform customers the update information for our products or suggest to clients to order the new model.
 7)End users or agent can make phone or fax or email for getting after-sale service for emergency and then fill the After-sale Support Form and send it to us by email or fax in time.
 8)HEPO INTERNATIONAL has a self-governed team for deal with after sales or complain business.

2,Complain Policy
 1)End users or agent can make phone or fax or email for complain for emergency and then fill the Complaint Form and send it to us by email or fax in time.The positive response time is same as upon clause in after-sale service.
 2)Customs' questions is first.If the goods received was breakdown or the package was damaged,we can arrange the new goods at once getting the inquiry from agent or purchaser along with pictures or other needed certified documents in our side.And we will bear half freight of sea shipment of this new order without any complain.The duty for the breakdown or damage of the head one can be deal after this new delivery.
 3)Once we delay delivery date,we will bear half freight for sea shipment for this order without any complain.
BBS Series Laminar Air Flow Cabinet (BBS-H1100)BBS Series Laminar Air Flow Cabinet (BBS-H1100)BBS Series Laminar Air Flow Cabinet (BBS-H1100)BBS Series Laminar Air Flow Cabinet (BBS-H1100)BBS Series Laminar Air Flow Cabinet (BBS-H1100)BBS Series Laminar Air Flow Cabinet (BBS-H1100)
BBS Series Laminar Air Flow Cabinet (BBS-H1100)BBS Series Laminar Air Flow Cabinet (BBS-H1100)BBS Series Laminar Air Flow Cabinet (BBS-H1100)

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now